Air Sampler Parts and Spare Parts for PM10, PM2.5 and TSP Samplers
Air sampler parts decide whether a monitoring train stays within its method: an inlet sets the cut point, a filter holder sets the deposit area, a motor housing sets the flow, and a filter support keeps the disc flat while air passes through it. T4 AIR SAMPLER manufactures those parts ourselves in Foshan, from inlets and holders to brushless motors, volumetric flow controllers and filter consumables, so a replacement matches the sampler already on your network.
What Counts as an Air Sampler Part
An air sampling train is a chain, and every link has a job. The inlet selects the particle size fraction, the filter holder locates the filter so the deposit area is known, the motor and housing produce and stabilize the flow, the controller holds that flow for the whole period, and the filter captures the mass that is finally weighed. Spares are therefore not accessories: a worn gasket or a distorted filter support changes the result just as surely as a mis-set flow rate.
Because we make the metal parts ourselves, you can order a single component, a complete train or a matched spares set, all to the same drawings.
Parts, Models and Where They Fit
The table below lists the air sampler parts we manufacture and where each one belongs in the train.
| Part | Model | Key data |
|---|---|---|
| TSP filter holder | TSP-FL | stainless steel and aluminum alloy |
| PM10 and PM2.5 filter holder | PM10-FL | high volume format |
| Low volume filter holder | PM10-FL-LV | 47 mm discs |
| Snap cover and filter paper cartridge set | FPC | 8 x 10 inch filter loading |
| Filter and motor housing sets | PM10-FL-BM, TSP-FL-BM, VFC-FL-BM | matched holder and housing |
| MFC blower motor housing | BMH01 | diameter 190 x 300 mm |
| VFC blower motor housing | BMH02 | diameter 190 x 264 mm |
| Volumetric flow controller | VFC | Venturi tube, diameter 107 x 190 x 300 mm, no moving parts |
| PUF inlet | PUF | 150 x 160 x 290 mm |
| Blower motor | BM-240 / BM-120 | 1062 to 1080 W, 240 V and 120 V |
| Brushless motor | BLM-240 | 1200 W, airflow above 3.5 m3/min |
| MFC and VFC control boxes | MFC-CTB, VFC-CTB | 4000 W SCR adjuster, 7 day timer |
| Digital flow meter | RMA14-SSV | 1 to 100 LPM, DWYER |
| Gas flow calibrator | SXF2024-30 | 300 mL/min to 30 L/min, plus or minus 1 percent of full scale |
| Aluminum calibrator housing | CH-01 | 320 x 240 x 240 mm |
| Connect pipe | CP-01 | diameter 38.5 x 306 mm |
| TSP low volume adapter | TSP-LV | diameter 69 x 79 mm, 47 mm filter |
| Moveable bracket | MB-01 | mast and roof mounting |
| Filter paper and support | 8 x 10 inch, 47 mm | glass fiber, PTFE membrane, support screen |
The VFC volumetric flow controller is a Venturi tube with no moving parts, so nothing inside it can wear or drift out of adjustment over a long deployment. It is also why the VFC and MFC housings differ: each is sized to the controller it carries.
How to Identify the Right Spare Part
Start with the model number on the nameplate of the sampler or the control box, then confirm the filter format, since an 8 x 10 inch holder and a 47 mm holder are not interchangeable. Next check the mounting: thread size, bolt pattern and motor housing diameter, because the housing must accept the motor and the controller the cabinet was built around. A photograph with a ruler in frame usually settles the remaining doubt.
Matching the flow controller to the motor housing matters more than it appears. The Venturi in the controller is sized for a flow range and the housing is sized for that controller, so a mismatch produces a flow that cannot be set or that drifts between visits. Where the two are supplied as a set, keep them together.
For unmanned stations, the BLM-240 brushless motor is the usual choice. It produces 1200 W and airflow above 3.5 m3/min, runs for more than 7 days continuously, and has no carbon brushes to replace, so no brush dust collects inside the housing. The BM-240 and BM-120 brushed blowers at 1062 to 1080 W remain the economical option for attended sites.
Materials, Finish and Manufacturing
Air sampler parts are made from aluminum alloy and stainless steel, anodized or powder coated. Aluminum alloy is used where weight matters, such as housings and cabinet bodies, and stainless steel where a surface must resist corrosion and abrasive dust. Anodizing gives a hard, even finish that does not flake, and powder coating is used on parts that face the weather directly.
Machining tolerances are held because the aerodynamics of an inlet depend on them. A jet bore, a holder face or a Venturi throat that is out of specification will shift the cut point or the flow, and no amount of calibration will recover the original method. Parts are packed with the machined faces protected.
Installation, Calibration and Maintenance
Fit the moveable bracket or the mounting plate first and check that the sampler stands level, then assemble the train upwards from the housing to the inlet. Confirm that the filter support screen sits flat before the filter is laid on it, and that the snap cover or cartridge closes without pinching the disc. A filter that is buckled or unsupported will not deliver a reliable mass.
After assembly, leak check the train and calibrate the flow with a gas flow calibrator, using the aluminum calibrator housing CH-01 where the method calls for it. Record the flow, the ambient conditions and the part numbers used, so a later change can be traced to a component. During service, inspect gaskets and seals, clean the blower and housing, check the controller for damage, and renew the filter support screen if it has lost its flatness.
Applications and Industries
Spare parts and consumables are bought by very different customers, and the program usually explains what they need:
- Monitoring networks keeping a mixed fleet of samplers in calibration
- Environmental agencies placing bulk orders of filters and holders
- Integrators building complete trains around our housings and controllers
- Industrial sites replacing motors and gaskets during planned shutdowns
- Research groups specifying a cut point or a filter format for a study
- Distributors holding stock of the fast-moving spares
Tell us the sampler model and the problem you are trying to fix, and we will identify the part and confirm it with a drawing before you order.
Packing, Shipping and Lead Time
Most air sampler parts ship from stock, which keeps a repair or a scheduled service on schedule. Machined items are protected with foam inside individual cartons, and consumables such as 8 x 10 inch glass fiber paper, 47 mm glass fiber paper, 47 mm PTFE membrane paper with 1.0 micrometer pores and the 47 mm filter support screen are boxed flat. Filter paper takes about 7 days to prepare, so order it early rather than after the hardware arrives.
We ship by air for urgent spares and by sea for bulk orders, and we provide a packing list with weights and carton dimensions so freight and customs clearance can be planned.
OEM, ODM and How to Order
We supply air sampler parts as OEM components and as ODM projects. That can mean a private label on a housing, a holder machined to your drawing, a filter size outside our standard range, a different connector or power standard on a control box, or a complete kit packed under your own part numbers for onward sale.
To order, send the model number or a photograph with dimensions, the quantity and the destination. We will confirm the part, the finish and the lead time, and issue a drawing for approval on modified items.
Air Sampler Parts Available from T4 AIR SAMPLER

Snap Cover and Filter Paper Cartridge Set
Snap cover and filter paper cartridge set for high volume air sampler PM2.5 and PM10 work.

Filter and Motor Housing Set for PM10/PM2.5
Filter and motor housing set for high volume air sampler cabinets, electronics not included.

Filter and Motor Housing Set for TSP
TSP filter and motor housing set for outdoor air sampling equipment.

Blower Motor Housing for Mass Flow Air Sampler
Blower motor housing BMH01 for mass flow high volume air sampler, MFC type.

Blower Motor Housing for Volumetric Flow Air Sampler
Blower motor housing BMH02 for volumetric flow air sampler, VFC type.

Volumetric Flow Controller (Venturi Tube)
Volumetric flow controller with no moving parts, holding 1.13 m3/min in an air sampler.

VFC Filter and Motor Housing
VFC filter and motor housing set, matched to the Venturi tube for volumetric flow sampling.

PUF Inlet for High Volume Air Sampler
PUF inlet air sampler accessory for semi-volatile organic compound sampling.

Cabinet for Double Channel Low Volume Sampler
Low volume air sampler cabinet for a two channel sampling train, powder coated aluminum.

Moveable Bracket for Outdoor Air Sampler
Air sampler bracket that lets the inlet be repositioned or the unit moved between sites.

Connect Pipe for PM10-LV and PM2.5 Impactor
Connect pipe air sampler part that sets the correct distance between inlet and impactor.

Filter Holder for PM10-LV and PM2.5 Impactor
Low volume filter holder taking standard 47 mm discs with an O-ring seal.

Control Pump and Box for Low Volume Air Sampler
Air sampler pump and control box, 3 to 30 L/min, single or double channel, rechargeable battery.

Blower Motor 120V / 240V for Air Sampler
Air sampler blower motor, 1062-1080 W, in 120 V and 240 V versions.

Brushless Blower Motor for Air Sampler
Brushless blower motor with no carbon brushes, running continuously for more than 7 days.

Digital Flow Meter 1-100 LPM
Flow meter for air sampler, 1 to 100 LPM, for setting and checking the sampling rate.

Gas Flow Calibrator 3-30 LPM
Air sampler calibration instrument covering 300 mL/min to 30 L/min at 1 percent accuracy.

MFC Control Box for High Volume Air Sampler
Air sampler control box with 4000 W SCR adjuster and 7 day programmable timer, MFC type.

VFC Control Box for High Volume Air Sampler
VFC control box with SCR power adjuster and weekly timer for volumetric flow samplers.

Aluminum Calibrator Housing Set
Calibrator housing in anodized aluminum, protecting a flow calibrator in the field.

Glass Fiber Filter Paper 8 x 10 inch
PM10 filter paper, ultrafine glass fiber, 8 x 10 inch, 100 pieces per box.

Glass Fiber Filter Paper 47 mm
47 mm filter paper in ultrafine glass fiber, 100 discs per box for low volume samplers.

PTFE Membrane Filter Paper 47 mm
PTFE filter paper, binder-free membrane with 1.0 micrometre pores, 50 per box.
Frequently Asked Questions
How do I find the right spare part for my air sampler?
Start with the model number on the sampler or control box nameplate, then note the filter format, the mounting thread or bolt pattern and the diameter of the motor housing. A photograph of the old part with a ruler in frame is often enough for us to confirm it. Send those details and we will match the part against our drawings before you order.
What is the difference between the MFC and the VFC blower motor housing?
Each housing is sized for the flow controller it carries. The BMH01 housing at diameter 190 x 300 mm is built for the MFC arrangement, and the BMH02 at diameter 190 x 264 mm is built for the VFC volumetric flow controller. Fitting the wrong housing means the controller cannot hold the intended flow, so the housing and controller should always be ordered as a matched pair.
Why choose a brushless motor for an unmanned station?
The BLM-240 brushless motor has no carbon brushes, so there is nothing to replace on a service visit and no brush dust inside the housing. It produces 1200 W with airflow above 3.5 m3/min and runs for more than 7 days of continuous operation. For a station that is visited rarely, that combination reduces both maintenance visits and the risk of a motor failure mid-period.
Why does the 47 mm filter support screen matter?
The support screen sits under the filter disc and keeps it flat when the pump pulls air through, so the deposit covers the area the calculation assumes. Without it, or with a screen that has lost its flatness, the disc can bow and tear, and the mass data becomes unreliable. It is a low cost part that protects the whole measurement.
What is the snap cover and filter paper cartridge set used for?
The FPC set holds an 8 x 10 inch filter so it can be handled, transported and loaded into the sampler without touching the deposit. Loading is normally done in the laboratory, where the filter is weighed and then carried to the site in its cartridge. That protects the sample from contamination and from the creasing that causes flow problems in the holder.
Send us your flow rate, size fraction and site conditions - we will recommend the right configuration and quote within one working day.
Request a Quote